Authorized Duff-Norton Service Center Since 1980
Calumet Chicago Company has been an authorized Duff-Norton air motor jack service center since 1980. We repair 228R, 326R, 528/536, 126/132/144 R, RX, CMJ and AMJ series 20 to 100 tons, at our shop in Highland, Indiana.
Call (708) 474-2343 or send your jack details and photos.
— Duff Norton Air Motor Jack Co.
Who makes Duff-Norton air motor jacks today
Duff-Norton air motor jacks are made by Duff Norton Air Motor Jack Co. in Billings, Montana (Who We Are). Parts and manuals come from that company.
Models we repair
- 228R, 20 tons
- 326R, 35 tons (326R guide)
- 528 / 536, 50 tons
- 126 / 144 and CMJ series, up to 100 tons
Older jacks may carry R, RX, AMJ or CMJ markings, and some older 100-ton models carry a 75-ton rating. Send a nameplate photo and we will identify the model. Full specifications are on our Duff Norton air motor jack specifications page.
Signs your air motor jack needs service
- Slow or weak lift at normal air pressure
- Jack drifts down or will not hold a load
- Air or oil leaks, or a noisy air motor
- Damage from a drop, overload or incident
Take the jack out of service and have it inspected if you see any of these signs. OSHA requires an inspection immediately before and after any abnormal load or shock, and at least every 6 months for jacks in regular use (OSHA 1910.244(a)(2)(vi)). See the inspection requirements below.
Our repair process
- Send the model, serial number, nameplate photo and symptoms.
- Get it to our shop. Ship it to Highland, IN, or ask us about local pickup. Drop-offs are welcome.
- We tear it down, evaluate it, and quote the work before we start.
- We repair it with OEM parts and test it to OEM performance specifications.
- Your jack ships back with our 6-month Repair Warranty.
Inspection requirements and our Preventative Maintenance Program
OSHA 29 CFR 1910.244 requires every jack to be thoroughly inspected at least once every 6 months when it is in constant or intermittent use at one location. It must also be inspected when it goes out of the shop for special work and when it returns, and immediately before and after any abnormal load or shock (OSHA 1910.244).
The ASME B30.1 jack standard also calls for a recorded periodic inspection, yearly for jacks in normal service, and recommends that an authorized service center or a qualified person perform it.
Our Preventative Maintenance Program covers that annual inspection. It includes complete disassembly, wear-part replacement, capacity testing, an inspection date marked on each jack, reports on request, and a reminder 30 days before each jack is due. Between annual visits, the OSHA 6-month inspection still applies.
Repair, refurbished or new
If a repair does not make sense, we sell new and refurbished Duff-Norton air motor jacks and take trade-ins. See Purchase / Trade-In. For fleets, our Preventative Maintenance Program keeps service scheduled.
Request a Duff-Norton jack repair quote
Call (708) 474-2343, Monday to Friday, 7:00 am to 3:30 pm Central, or email sales@calumetchicago.com. See all railroad and industrial jack repair services.